Problem Failure Cause Solution
1.Ram off the tool when turning have the striae. Low pressure of balance cylinder, nut big clearance, pressure plate and oblique iron clearance is big. Reasonable adjustment pressure, nut clearance, clearance of retighten clamp and oblique iron.
2.Beam don't lifting. Pressure is not enough, air switch trip. Adjust pressure,put air switch.
3.Can't change tap position. Low oil pressure, lock lever is not regular. Adjust the pressure, adjust the lock lever position.
4.When machining inner hole and excircle engender tapering. Vertical tool post ram and workbench can't keep verticality. Readjust the verticality of tool post and workbench.
5.The workbench do not turn when it is normal working. Air switch trip, frequency converters protection, oil pressure is not enough. Check the switch is whether or not trip, if frequency changer protection, regulate the pressure.
6. Fast moving tool post immobility. Fast clutch without electricity or clutch burn out. Check the voltage is normal or not, replace the clutch.

 